Drives per rack unit
|
- 6
|
Drive form factor
|
- 3.5” large form factor
|
Drive carrier | |
|
Performance disk drives
|
- DS4243: 300GB, 450GB, and 600GB at 15k RPM
- DS4246: Not supported
|
Controllers supported with
performance disk drives
|
- FAS2000 series
- FAS2200 series
- FAS/V3070
- FAS/V3100 series
- FAS/V3200 series
- FAS/V6000 series
- FAS/V6200 series
|
Data ONTAP version required for performance disk drives |
- 7.3.3P2 or later, 8.0P1 or later
| Self-encrypting disk drives
|
- DS4243: 600GB at 15k RPM,
128-bit AES,FIPS 140-2 compliant
- DS4246: Not supported
|
|
Controllers supported with
self-encrypting disk drives | |
|
Controllers supported with
solid state drives in data aggregates
|
- FAS2200 series
- FAS/V3160
- FAS/V3170
- FAS/V3200 series
- FAS/V6040
- FAS/V6080
- FAS/V6200 series
|
Controllers supported in configurations using only
solid state drives
|
- FAS2200 series
- FAS/V3200 series
- FAS/V6210
- FAS/V6240
| Data ONTAP version required for solid state drives
| - 8.0.1 or later for most systems;
- 8.1 or later is required for FAS2240-2 and FAS2240-4;
- 8.1.1 or later is required for Cluster-Mode, all-SSD, and Flash Pool configurations
|
Mixed SSDs and HDDs in the same disk shelf
|
- DS4243 and DS4246:
100GB SSDs with 1TB HDDs;
100GB SSDs with 3TB HDDs
|
Shelf architecture and I/O bandwidth |
- DS4243: SAS operating at 3Gbps;
- DS4246: SAS operating at 6Gbps;
- Both: Connections require PCIe SAS host bus adapter card or available embedded SAS port.
| Shelf I/O modules
| - FAS4243: Dual IOM3 modules;
- FAS4246: Dual IOM6 modules
| Interface controller
| - DS4243: 3Gbps SAS
- DS4246: 6Gbps SAS
|
| Power supply/cooling fans |
- Redundant, hot-pluggable, integrated power supply/fan assemblies;
Dual supplies required for high-capacity disk drives and SSDs;
Quadruple supplies required for performance disk drives and self-encrypting disk drives.
| AC input power voltage
(autoranging, VRMS) |
- 100–120V or 200–240V
|
AC input power frequency
|
- 50–60 Hz
|
DC input power
|
- Not Available
|
Weight—fully loaded
| |
|
Dimensions
|
- Height: 7 in. (17.8 cm)
- Width: 19 in. (48.3 cm)
- Depth: 24 in. (61 cm)
|
Clearance Dimensions
|
- Front—cooling: 6 in. 15.3 cm)
- Front—maintenance: 12 in. (30.5 cm)
- Rear—cooling and maintenance: 25 in. (55.9 cm)
|
Operating acoustic noise
|
- 7.0 bels LwAd (4 PCMs)
|
Temperature
|
- Operating: 50° F to 104° F (10° C to 40° C)
- Nonoperating: –40° F to 158° F (–40° C to 70° C)
|
Relative humidity
|
- Operating: 20% to 80% noncondensing;
- Nonoperating: 10 to 95% noncondensing
|
Altitude
|
- Operating: 0 to 10,000 ft (0 to 3,045 m)
- Nonoperating: –1,000 to 40,000 ft (–305 to 12,192 m)
| | | | | | | | | |
| | |
| | | | | | | |