Skip to main content

Filer Head

SKU:
V3020-BASE

Description


This is a Refurbished NetApp V3020 Base Filer Head Unit. System does not include hard drives and software. This system includes a 3 Year Next Business Day Warranty.


Get advanced storage efficiency, data protection, and data management features while maintaining your current storage investments. The V-Series open storage controllers let you manage disk arrays from EMC, IBM, Hewlett-Packard, Hitachi Data Systems, and other major storage vendors as if they were NetApp storage. The current generation of NetApp disk shelves can also be used with V-Series controllers, giving you more choice and flexibility for capacity expansion.


Dramatically increase your disk utilization and reclaim stranded capacity with thin provisioning and deduplication for primary storage, not just secondary storage.


Use our Snapshot software, the original and most functional point-in-time copy technology, to protect your data with no performance impact and minimal consumption of storage space. Replicate data across your global network at high speeds simply, efficiently, and flexibly with SnapMirror for disaster recovery.


Accelerate application development and testing by using our FlexClone technology to instantly replicate data volumes and data sets as transparent, virtual copies. NetApp clones increase productivity and save storage space without compromising performance.


Take advantage of these features whether you use the V-Series to provide file services, to store block-based data, or both. Our V-Series controllers give you this flexibility with native support for FC SAN, FCoE, iSCSI, NFS, and CIFS protocols.


For more information: Please e-mail us at sales@vectordata.com. We can customize systems to your needs.


Specifications:


Technical Highlights
Maximum RAID Group Sizes RAID-6 (RAID-DP)
FC-28 (26 data disks plus 2 parity disks)
SATA-16 (14 data disks plus 2 parity disks)
RAID-4
FC-14 (13 data disks plus 1 parity disk)
SATA-7 (6 data disks plus 1 parity disk)

RAID-6+RAID1 or RAID4+RAID1 (SyncMirror)
SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; iSCSI
File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS
Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts
LUNs Up to 1,024
FlexVol Volumes Up to 500 per controller
Volume/Aggregate Size 16TB
Snapshot Copies Up to 127,000
Number of Supported Hosts Up to 4 ports per controller configured as front-end (host) connectivity ports
Up to 4 directly connected servers (per controller and per active/active configuration)
Up to 256 SAN connected servers (per controller and per active/active configuration)
Supported Configurations Highly Available Controller Configurations
Active/active controller with Controller Failover (CFO), active/active controller with stretch (non-switch) MetroCluster, active/active controller with Fabric Attached MetroCluster

Highly Available Back-End (Disk) Configurations
Dual-path, Multipath HA Storage
Reliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
Management Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
Security Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role Based Access Control (RBAC)

Scalability V3020
Active/Active
Configuration
Single
Controller
Max. Raw Capacity 84TB 84TB
Max. Number of Disk Drives 168 168
Max. Drives per Back-End (Disk) FC Loop 84 84
ECC Memory 4GB 2GB
Nonvolatile Memory 1GB 512MB

I/O V3020
Active/Active
Configuration
Single
Controller
Onboard (fixed) Fibre Channel Ports (target or initiator) 8 ports of 2Gb 4 ports of 2Gb
Onboard (fixed) GbE Ports 8 4
Modular I/O Slots 6 3
RAID-6 is the recommended configuration for drives greater than 144 GB.
RLM module is an optional capability on the V3020 that is included at no charge with SupportEdge Premium contract.

I/O Card Support V3020
Active/Active
Configuration
Single
Controller
Dual FC Disk Adapters (max.) 6 3
Dual 4Gb FC Target Adapters (max.) 4 2
Quad 4Gb FC Disk/Tape Adapters (max.) 6 3
Dual FC -Tape Adapters (max.) 6 3
Dual-port SCSI HBA 6 3
Optional Network Connectivity (max.)
Quad GbE TOE (copper) cards
Single 10GbE TOE (fiber) cards
Dual GbE (copper or fiber) cards
Dual iSCSI (copper or fiber) host adapter


4
4
6
6


2
2
3
3

Storage Specifications
Disk Shelves Supported (Fibre Channel, SATA) DS14, DS14mk2 FC, DS14mk2AT
Each w/14 low-profile slots for FC and SATA disk drives
Disk Drive Support Disks Supported on New Configurations
FC-144GB, 300GB disks
SATA-250GB, 500GB disks

Disks Supported for Legacy (Controller Upgrade) Configurations
FC-36GB, 72GB, 144GB, 300GB disks
SATA-250GB, 320GB, 500GB disks
Disk Shelf Support Shelves Supported on New Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX

Shelves Supported for Legacy (Controller Upgrade) Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX
LRC
Disk Drive Storage Shelf Interface Fibre Channel-Arbitrated Loop (FC-AL)
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
AC Power/Max. Current 100 to 120VAC/3.95A; 200 to 240VAC/1.9A
Thermal Rating 1,215 Btu/hr (fully loaded shelf)
Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded
V3020 has PCI-x I/O slots.
Protection Manager was previously known as Business Continuance Option
Operations Manager was previously known as Data Fabric Manager (DFM).

FC Switch Support- Tape/SAN
Vendor Model
Brocade Silkworm 2400/2800 (TapeSAN only)
Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E
McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
Cisco MDS 9120/9140/9216/9506/9509/9513
FC = Fibre Channel; LVD = Low Voltage Differential

NetApp Systems Cabinet
20A and 30A single phase cabinets.

20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

30A Cabinet - Includes 2 power cords with NEMA L6-30 or IEC 309 connectors
20A Cabinet - a single controller and 13 DS-14 shelves; two controllers and 12 DS-14 shelves

30A Cabinet - a single controller and 12 DS-14 shelves; two controllers and 11 DS-14 shelves
AC Power 200 to 240VAC
Current Redundant power
20A Cabinet - Maximum 32A total
30A Cabinet - Maximum 24A total
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)

System Specifications Active/Active Configuration Single Controller Configuration
AC and DC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240VAC only) 100 to 240VAC, 7.66 to 3.50A, 50/60Hz

200 to 240VAC, 4.00 to 3.50A, 50/60Hz

48VDC, 14.8A, 710W
100 to 240VAC, 3.83 to 1.75A, 50/60Hz

200 to 240VAC, 2.00 to 1.75A, 50/60Hz

48VDC, 7.4A, 355W
Thermal Rating 2430 Btu/hr 1215 Btu/hr (note: Watts x 3.4129)
Weight 150 lb (68 kg) 75 lb (34 kg)
Height 10.24" (26 cm), fits into 6U space 5.12" (13 cm), fits into 3U space
Width 19" IEC rack-compliant (17.7", 44.9 cm)
Depth 24" (61 cm), 30" (76.2 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity 10 C to 40 C (50 F to 104 F); at
Non-operating Temperature and Relative Humidity -40 C to 65 C (-40 F to 149 F); 10% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise < 54 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear
Compliance RoHS-compliant
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI

Filer Head V3020-BASE